Assessment Year | 1994 |
---|---|
Principal Product | Organic Chemicals |
NAICS |
n/a
|
SIC | 2869: Industrial Organic Chemicals, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
100,000
ft2
|
Annual Production | 8,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $472,741 | 7,261,723 |
kWh
|
$0.065 |
Natural Gas | $163,603 | 33,018 |
MMBtu
|
$4.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $69,350 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,168 | $1,200 |
$2,168
33,705
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $677 | $2,791 |
$677
10,551
kWh
|
- | |
03 | 2.7135: Install occupancy sensors | $252 | $128 |
$252
4,689
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $404 | $600 |
$404
4,982
kWh
|
- | |
05 | 2.4133: Use most efficient type of electric motors | $4,683 | $9,153 |
$4,683
70,047
kWh
|
- | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,343 | $12,000 |
$7,343
133,646
kWh
|
- | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $29,488 | $53,050 |
$29,488
508,499
kWh
|
- | |
08 | 2.2414: Use waste heat from hot flue gases to preheat | $6,270 | $2,600 | - |
$6,270
-
MMBtu
|
|
09 | 2.2621: Modify refrigeration system to operate at a lower pressure | $18,065 | $42,800 |
$18,065
277,843
kWh
|
- | |
TOTAL RECOMMENDED | $69,350 | $124,322 |
$63,080
1,043,962
kWh
|
$6,270
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs