ITAC Assessment: UF0094
ITAC logo
ITAC Assessment: UF0094
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1994
Principal Product Mattresses and Boxsprings
NAICS
n/a
SIC 2515: Mattresses, Foundations, and Convertible Beds
Sales Range $50
M
to 100
M
# of Employees 250
Plant Area 265,000
ft2
Annual Production 400,000
pieces
Production Hrs. Annual 5,304
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $99,638 1,664,127
kWh
Other Energy $1,644 15
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $24,475 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $2,145 $687 $2,145
35,756
kWh
02 2.7135: Install occupancy sensors $642 $256 $642
12,896
kWh
03 2.7144: Install spectral reflectors / delamp $3,307 $11,712 $3,307
43,083
kWh
04 2.7111: Reduce illumination to minimum necessary levels $5,419 $1,350 $5,419
81,770
kWh
05 2.4133: Use most efficient type of electric motors $440 $1,045 $440
7,327
kWh
06 2.7134: Use photocell controls $2,113 $2,400 $2,113
42,204
kWh
07 2.7232: Replace existing hvac unit with high efficiency model $6,412 $18,200 $6,412
106,682
kWh
08 2.3132: Recharge batteries on during off-peak demand periods $961 - $961
-
kWh
09 2.7263: Lower compressor pressure through a/c system modification $1,520 $3,200 $1,520
30,481
kWh
10 2.7421: Reduce glazed areas in buildings $1,516 $300 $1,516
25,205
kWh
TOTAL RECOMMENDED $24,475 $39,150 $24,475
385,404
kWh
TOTAL IMPLEMENTED - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs