Assessment Year | 1994 |
---|---|
Principal Product | Solar Control Products |
NAICS |
n/a
|
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $10 M to 50M |
# of Employees | 135 |
Plant Area |
100,000
ft2
|
Annual Production | 80,000,000
thousand feet
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $174,009 | 2,666,764 |
kWh
|
$0.065 |
Natural Gas | $182,205 | 27,215 |
MMBtu
|
$6.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,389 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,304 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,526 | $431 |
$2,526
38,980
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $872 | $2,543 |
$872
13,482
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $2,828 | $1,964 |
$2,828
43,376
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $811 | $775 |
$811
12,603
kWh
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,078 | $500 |
$1,078
16,706
kWh
|
- | |
06 | 2.2622: Replace existing chiller with high efficiency model | $3,288 | $10,000 |
$3,288
50,703
kWh
|
- | |
07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $8,164 | $1,000 | - |
$8,164
-
MMBtu
|
|
08 | 2.7232: Replace existing hvac unit with high efficiency model | $2,997 | $3,600 |
$2,997
45,721
kWh
|
- | |
09 | 2.1213: Direct warmest air to combustion intake | $2,825 | $2,600 | - |
$2,825
-
MMBtu
|
|
TOTAL RECOMMENDED | $25,389 | $23,413 |
$14,400
221,571
kWh
|
$10,989
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,304 | $5,438 |
$7,304
112,544
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs