| Assessment Year | 1994 |
|---|---|
| Principal Product | steel fabricated products |
| NAICS |
n/a
|
| SIC | 3441: Fabricated Structural Metal |
| Sales Range | $5 M to 10M |
| # of Employees | 87 |
| Plant Area |
76,000
ft2
|
| Annual Production | 5,000
ton
|
| Production Hrs. Annual | 5,616
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $61,188 | 860,492 |
kWh
|
$0.071 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,331 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,347 | $2,246 |
$5,347
75,322
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,449 | $1,820 |
$1,449
27,257
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $534 | $1,126 |
$534
7,620
kWh
|
|
| 04 | 2.7135: Install occupancy sensors | $1,191 | $320 |
$1,191
21,395
kWh
|
|
| 05 | 2.7232: Replace existing hvac unit with high efficiency model | $2,372 | $1,940 |
$2,372
35,463
kWh
|
|
| 06 | 2.4133: Use most efficient type of electric motors | $3,008 | $1,960 |
$3,008
42,497
kWh
|
|
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,430 | $750 |
$1,430
20,223
kWh
|
|
| TOTAL RECOMMENDED | $15,331 | $10,162 |
$15,331
229,777
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs