| Assessment Year | 1994 |
|---|---|
| Principal Product | Polystyrene Cups |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 84 |
| Plant Area |
125,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 8,500
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $257,214 | 3,857,855 |
kWh
|
$0.067 |
| Natural Gas | $612,434 | 144,862 |
MMBtu
|
$4.23 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $197,384 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,524 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $9,252 | $9,802 |
$9,252
138,042
kWh
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,048 | $1,584 |
$1,048
15,533
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,272 | $594 |
$5,272
78,546
kWh
|
- | |
| 04 | 2.7135: Install occupancy sensors | $1,257 | $512 |
$1,257
21,395
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $147 | $200 |
$147
1,758
kWh
|
- | |
| 06 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $180,408 | $500,000 | - | $180,408 | |
| TOTAL RECOMMENDED | $197,384 | $512,692 |
$16,976
255,274
kWh
|
$180,408 | ||
| TOTAL IMPLEMENTED | $14,524 | $10,396 |
$14,524
216,588
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs