Assessment Year | 1993 |
---|---|
Principal Product | Gaskets and Shims |
NAICS |
n/a
|
SIC | 3053: Gaskets, Packing, and Sealing Devices |
Sales Range | $5 M to 10M |
# of Employees | 65 |
Plant Area |
52,000
ft2
|
Annual Production | 17,000,000
pieces
|
Production Hrs. Annual | 4,700
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $91,645 | 1,637,456 |
kWh
|
$0.056 |
Natural Gas | $260,040 | 57,009 |
MMBtu
|
$4.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,788 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,413 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.2221: Use immersion heating in tanks, melting pots, etc | $3,720 | $1,200 |
$3,720
63,599
kWh
|
|
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,567 | - |
$4,567
-
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $3,378 | $2,049 |
$3,378
60,961
kWh
|
|
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,107 | $3,050 |
$2,107
37,515
kWh
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $880 | $750 |
$880
15,826
kWh
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,781 | $732 |
$1,781
31,946
kWh
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $94 | $147 |
$94
1,465
kWh
|
|
08 | 2.7135: Install occupancy sensors | $408 | $128 |
$408
7,327
kWh
|
|
09 | 2.7232: Replace existing hvac unit with high efficiency model | $624 | $2,250 |
$624
11,137
kWh
|
|
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $884 | $3,563 |
$884
15,826
kWh
|
|
11 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,345 | $800 |
$3,345
59,789
kWh
|
|
TOTAL RECOMMENDED | $21,788 | $14,669 |
$21,788
305,391
kWh
|
||
TOTAL IMPLEMENTED | $13,413 | $2,732 |
$13,413
155,334
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs