Assessment Year | 2017 |
---|---|
Principal Product | Juice and Puree |
NAICS | 311411: Frozen Fruit, Juice, and Vegetable Manufacturing |
SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
Sales Range | $50 M to 100M |
# of Employees | 110 |
Plant Area |
44,227
ft2
|
Annual Production | 136
units
|
Production Hrs. Annual | 7,296
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $184,623 | 2,298,203 |
kWh
|
$0.080 | |
Electricity Demand | $17,509 | 3,070 |
kW-mo/yr
|
$5.70 | |
Natural Gas | $242,268 | 70,640 |
MMBtu
|
$3.43 | |
Waste Disposal Costs | |||||
Water Usage | $67,243 | 30,902 |
Tgal
|
$2.18 | |
Water Disposal | $272,239 | 28,029 |
Tgal
|
$9.71 | |
TOTAL YEARLY COSTS | $783,882 | ||||
RECOMMENDED SAVINGS* | $535,529 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | Personnel Changes Savings | Primary Product Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 4.111: Add equipment/ operators to reduce production bottleneck | $190,250 | $7,842 | - | - |
$(-2,950.0)
-
MMBtu
|
- | - | - | $193,200 | - | |
02 | 4.611: Begin a practice of predictive / preventative maintenance | $78,503 | $7,018 | - | - | - | - | - | - | - | $78,503 | |
03 | 4.651: Install back-up equipment | $219,130 | $45,000 | - | - | - | - | - | $219,130 | - | - | |
04 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $29,962 | $12,100 | - | - | - | - | - | $29,962 | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,605 | $10,606 |
$9,043
130,760
kWh
|
$562
-
kW-mo/yr
|
- | - | - | - | - | - | |
06 | 3.4151: Minimize water usage | $8,079 | $15,125 | - | - | - |
$3,403
-
Tgal
|
$4,676
-
Tgal
|
- | - | - | |
TOTAL RECOMMENDED | $535,529 | $97,691 |
$9,043
130,760
kWh
|
$562
-
kW-mo/yr
|
$(-2,950.0)
-
MMBtu
|
$3,403
-
Tgal
|
$4,676
-
Tgal
|
$249,092 | $193,200 | $78,503 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | Personnel Changes Savings | Primary Product Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs