Assessment Year | 1992 |
---|---|
Principal Product | HYDRAULIC HOSES |
NAICS |
n/a
|
SIC | 3052: Rubber and Plastics Hose and Belting |
Sales Range | $10 M to 50M |
# of Employees | 500 |
Plant Area |
n/a
|
Annual Production | 40,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $985,188 | 16,537,515 |
kWh
|
$0.060 |
Natural Gas | $187,283 | 40,283 |
MMBtu
|
$4.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $68,441 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $34,691 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,148 | $408 |
$2,148
35,756
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $462 | $2,465 |
$462
7,620
kWh
|
- | |
03 | 2.7144: Install spectral reflectors / delamp | $3,902 | $12,240 |
$3,902
65,064
kWh
|
- | |
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $22,821 | - |
$22,821
-
kWh
|
- | |
05 | 2.4133: Use most efficient type of electric motors | $9,260 | $55,871 |
$9,260
154,455
kWh
|
- | |
06 | 2.7233: Use properly designed and sized hvac equipment | $18,660 | $105,000 |
$18,660
310,961
kWh
|
- | |
07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $11,188 | $1,000 | - |
$11,188
-
MMBtu
|
|
TOTAL RECOMMENDED | $68,441 | $176,984 |
$57,253
573,856
kWh
|
$11,188
-
MMBtu
|
||
TOTAL IMPLEMENTED | $34,691 | $58,744 |
$34,691
197,831
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs