Assessment Year 1992
Principal Product EMERGENCY/FIRE VEHICLES
NAICS
n/a
SIC 3711: Motor Vehicles and Passenger Car Bodies
Sales Range $50
M
to 100
M
# of Employees 300
Plant Area
n/a
Annual Production 750
pieces
Production Hrs. Annual 4,680
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $177,556 2,634,818
kWh
Natural Gas $9,582 1,899
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $57,393 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $6,207

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $4,391 $2,740 $4,391
65,944
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $1,267 $6,192 $1,267
19,050
kWh
03 2.7144: Install spectral reflectors / delamp $20,326 $35,925 $20,326
303,341
kWh
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,426 $550 $4,426
65,944
kWh
05 2.4133: Use most efficient type of electric motors $1,492 $15,213 $1,492
22,274
kWh
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,087 $1,775 $2,087
31,067
kWh
07 2.7111: Reduce illumination to minimum necessary levels $10,285 - $10,285
153,576
kWh
08 2.3131: Reschedule plant operations or reduce load to avoid peaks $12,830 - $12,830
-
kWh
09 2.7233: Use properly designed and sized hvac equipment $289 $1,100 $289
4,396
kWh
TOTAL RECOMMENDED $57,393 $63,495 $57,393
665,592
kWh
TOTAL IMPLEMENTED $6,207 $16,863 $6,207
92,614
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs