Assessment Year | 1992 |
---|---|
Principal Product | PVC PIPE AND FITTINGS |
NAICS |
n/a
|
SIC | 3084: Plastics Pipe |
Sales Range | $5 M to 10M |
# of Employees | 100 |
Plant Area |
n/a
|
Annual Production | 140,000,000
pieces
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,148,672 | 18,119,871 |
kWh
|
$0.063 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,616 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,492 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,439 | $5,421 |
$1,439
23,154
kWh
|
|
02 | 2.7144: Install spectral reflectors / delamp | $28,591 | $9,720 |
$28,591
448,710
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $94 | $643 |
$94
1,465
kWh
|
|
04 | 2.7233: Use properly designed and sized hvac equipment | $1,160 | $1,320 |
$1,160
18,757
kWh
|
|
05 | 2.4133: Use most efficient type of electric motors | $2,332 | $16,490 |
$2,332
37,515
kWh
|
|
TOTAL RECOMMENDED | $33,616 | $33,594 |
$33,616
529,601
kWh
|
||
TOTAL IMPLEMENTED | $3,492 | $17,810 |
$3,492
56,272
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs