Assessment Year | 1991 |
---|---|
Principal Product | VENEER BOARDS/WOOD CHIPS |
NAICS |
n/a
|
SIC | 2435: Hardwood Veneer and Plywood |
Sales Range | $1 M to 5M |
# of Employees | 68 |
Plant Area |
n/a
|
Annual Production | 4,000
thousand feet
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $43,003 | 601,114 |
kWh
|
$0.072 |
Fuel Oil #6 | $84,832 | 23,587 |
MMBtu
|
$3.60 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,322 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #6 Savings |
---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,858 | $3,000 | - |
$2,858
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $220 | - |
$220
2,931
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $280 | $281 |
$280
3,810
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $869 | - |
$869
12,016
kWh
|
- | |
05 | 2.7233: Use properly designed and sized hvac equipment | $95 | $200 |
$95
1,465
kWh
|
- | |
TOTAL RECOMMENDED | $4,322 | $3,481 |
$1,464
20,222
kWh
|
$2,858
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs