| Assessment Year | 1991 |
|---|---|
| Principal Product | VENEER BOARDS/WOOD CHIPS |
| NAICS |
n/a
|
| SIC | 2435: Hardwood Veneer and Plywood |
| Sales Range | $1 M to 5M |
| # of Employees | 68 |
| Plant Area |
n/a
|
| Annual Production | 4,000
thousand feet
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $43,003 | 601,114 |
kWh
|
$0.072 |
| Fuel Oil #6 | $84,832 | 23,587 |
MMBtu
|
$3.60 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,322 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #6 Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,858 | $3,000 | - |
$2,858
-
MMBtu
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $220 | - |
$220
2,931
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $280 | $281 |
$280
3,810
kWh
|
- | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $869 | - |
$869
12,016
kWh
|
- | |
| 05 | 2.7233: Use properly designed and sized hvac equipment | $95 | $200 |
$95
1,465
kWh
|
- | |
| TOTAL RECOMMENDED | $4,322 | $3,481 |
$1,464
20,222
kWh
|
$2,858
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs