Assessment Year | 2016 |
---|---|
Principal Product | Mushroom packaging |
NAICS | 311421: Fruit and Vegetable Canning |
SIC | 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies |
Sales Range | $10 M to 50M |
# of Employees | 215 |
Plant Area |
260,000
ft2
|
Annual Production | 14,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $424,452 | 6,728,783 |
kWh
|
$0.063 |
Electricity Demand | $43,538 | 13,606 |
kW-mo/yr
|
$3.20 |
Electricity Fees | $8,961 | - |
|
- |
Natural Gas | $102,807 | 29,548 |
MMBtu
|
$3.48 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,695 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,030 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,470 | $5,000 |
$4,470
71,000
kWh
|
- | - | |
02 | 2.2623: Minimize condenser cooling water temperature | $1,905 | - |
$1,905
30,244
kWh
|
- | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $1,405 | $90 |
$1,115
17,700
kWh
|
$290
-
kW-mo/yr
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,420 | $600 |
$1,330
21,100
kWh
|
$90
-
kW-mo/yr
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,205 | $685 |
$255
4,040
kWh
|
$20
-
kW-mo/yr
|
$930 | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $990 | $1,360 |
$925
14,670
kWh
|
$65
-
kW-mo/yr
|
- | |
07 | 2.2625: Chill water to the highest temperature possible | $760 | - |
$760
12,030
kWh
|
- | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $540 | $7 |
$505
8,000
kWh
|
$35
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $12,695 | $7,742 |
$11,265
178,784
kWh
|
$500
-
kW-mo/yr
|
$930 | ||
TOTAL IMPLEMENTED | $10,030 | $7,742 |
$8,600
136,510
kWh
|
$500
-
kW-mo/yr
|
$930 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs