| Assessment Year | 1991 |
|---|---|
| Principal Product | THERMOMETERS & PROBES |
| NAICS |
n/a
|
| SIC | 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products |
| Sales Range | $1 M to 5M |
| # of Employees | 34 |
| Plant Area |
n/a
|
| Annual Production | 18,000
pieces
|
| Production Hrs. Annual | 2,275
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $24,422 | 255,862 |
kWh
|
$0.095 |
| LPG | $613 | 39 |
MMBtu
|
$15.72 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,114 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,114 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $408 | - |
$408
4,396
kWh
|
|
| 02 | 2.7144: Install spectral reflectors / delamp | $2,525 | $8,430 |
$2,525
24,912
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $67 | $265 |
$67
586
kWh
|
|
| 04 | 2.7233: Use properly designed and sized hvac equipment | $612 | $420 |
$612
6,448
kWh
|
|
| 05 | 2.7492: Use proper thickness of insulation on building envelope | $2,374 | $4,180 |
$2,374
24,912
kWh
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $128 | $50 |
$128
1,465
kWh
|
|
| TOTAL RECOMMENDED | $6,114 | $13,345 |
$6,114
62,719
kWh
|
||
| TOTAL IMPLEMENTED | $6,114 | $13,345 |
$6,114
62,719
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs