| Assessment Year | 1991 |
|---|---|
| Principal Product | PVC PIPE AND FITTINGS |
| NAICS |
n/a
|
| SIC | 3084: Plastics Pipe |
| Sales Range | $5 M to 10M |
| # of Employees | 130 |
| Plant Area |
n/a
|
| Annual Production | 109,500,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $788,939 | 19,365,475 |
kWh
|
$0.041 |
| LPG | $68,378 | 6,432 |
MMBtu
|
$10.63 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $36,164 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $36,164 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,045 | $4,157 |
$3,045
74,736
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $550 | $1,831 |
$550
13,482
kWh
|
|
| 03 | 2.7144: Install spectral reflectors / delamp | $4,864 | $1,500 |
$4,864
112,837
kWh
|
|
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $3,887 | - |
$3,887
95,252
kWh
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $2,153 | $11,146 |
$2,153
52,755
kWh
|
|
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,903 | $1,450 |
$1,903
46,600
kWh
|
|
| 07 | 2.4322: Use or replace with energy efficient substitutes | $19,532 | $60,000 |
$19,532
478,605
kWh
|
|
| 08 | 2.7234: Use heat pump for space conditioning | $230 | - |
$230
5,569
kWh
|
|
| TOTAL RECOMMENDED | $36,164 | $80,084 |
$36,164
879,836
kWh
|
||
| TOTAL IMPLEMENTED | $36,164 | $80,084 |
$36,164
879,836
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs