| Assessment Year | 2026 |
|---|---|
| Principal Product | Retail/Strip Mall |
| NAICS | 531120: Lessors of Nonresidential Buildings (except Miniwarehouses) |
| SIC | 6512: Operators of Nonresidential Buildings |
| Sales Range | less than $500 k |
| # of Employees | 100 |
| Plant Area |
32,000
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 3,500
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $58,089 | 363,053 |
kWh
|
$0.16 | |
| Natural Gas | $17,880 | 557 |
MMBtu
|
$32.10 | |
| Waste Disposal Costs | |||||
| Water Usage | $2,000 | 170 |
Tgal
|
$11.76 | |
| TOTAL YEARLY COSTS | $77,969 | ||||
| RECOMMENDED SAVINGS* | $73,480 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,311 | $6,000 |
$1,311
8,193
kWh
|
- | |
| 02 | 2.7232: Replace existing hvac unit with high efficiency model | $2,365 | $15,000 |
$2,002
12,511
kWh
|
$363
-
MMBtu
|
|
| 03 | 2.7226: Use computer programs to optimize hvac performance | $4,602 | $5,000 |
$2,788
17,427
kWh
|
$1,814
-
MMBtu
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,916 | $15,000 |
$4,916
30,725
kWh
|
- | |
| 05 | 2.9114: Use solar heat to make electricty | $60,286 | $450,000 |
$60,286
376,788
kWh
|
- | |
| TOTAL RECOMMENDED | $73,480 | $491,000 |
$71,303
445,644
kWh
|
$2,177
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs