Assessment Year | 2025 |
---|---|
Principal Product | book rental |
NAICS | 519120: Libraries and Archives |
SIC | 8231: Libraries |
Sales Range | less than $500 k |
# of Employees | 12 |
Plant Area |
27,000
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 3,432
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $60,418 | 491,977 |
kWh
|
$0.12 | |
Natural Gas | $7,551 | 628 |
MMBtu
|
$12.03 | |
Waste Disposal Costs | |||||
Water Usage | $1 | 1 |
Tgal
|
$1.00 | |
TOTAL YEARLY COSTS | $67,970 | ||||
RECOMMENDED SAVINGS* | $42,002 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $11,529 | $28,000 |
$11,529
96,072
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,186 | $3,750 |
$3,186
26,546
kWh
|
- | |
03 | 2.9114: Use solar heat to make electricty | $20,580 | $273,000 |
$20,580
171,500
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $356 | $110 |
$356
2,969
kWh
|
- | |
05 | 2.7234: Use heat pump for space conditioning | $6,351 | $81,000 |
$(-907.0)
(-7,566)
kWh
|
$7,258
-
MMBtu
|
|
TOTAL RECOMMENDED | $42,002 | $385,860 |
$34,744
289,521
kWh
|
$7,258
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs