Assessment Year | 2024 |
---|---|
Principal Product | Religious |
NAICS | 813110: Religious Organizations |
SIC | 8661: Religious Organizations |
Sales Range | less than $500 k |
# of Employees | 61 |
Plant Area |
64,000
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 1,500
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $47,551 | 443,342 |
kWh
|
$0.11 | |
Natural Gas | $23,661 | 2,386 |
MMBtu
|
$9.92 | |
Waste Disposal Costs | |||||
Water Usage | $1 | 1 |
Tgal
|
$1.00 | |
TOTAL YEARLY COSTS | $71,213 | ||||
RECOMMENDED SAVINGS* | $10,572 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $9,350 | $130,000 |
$9,350
85,000
kWh
|
- | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $880 | - |
$880
8,000
kWh
|
- | |
03 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $342 | $20,000 |
$275
2,500
kWh
|
$67
-
MMBtu
|
|
TOTAL RECOMMENDED | $10,572 | $150,000 |
$10,505
95,500
kWh
|
$67
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs