| Assessment Year | 2024 |
|---|---|
| Principal Product | Religious |
| NAICS | 813110: Religious Organizations |
| SIC | 8661: Religious Organizations |
| Sales Range | less than $500 k |
| # of Employees | 3 |
| Plant Area |
3,000
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 1,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $662 | 2,543 |
kWh
|
$0.26 | |
| Natural Gas | $318 | 61 |
MMBtu
|
$5.20 | |
| Other Gas | $660 | 61 |
MMBtu
|
$10.78 | |
| Waste Disposal Costs | |||||
| Water Usage | $1 | 1 |
Tgal
|
$1.00 | |
| TOTAL YEARLY COSTS | $1,641 | ||||
| RECOMMENDED SAVINGS* | $1,841 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $1,771 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $793 | $5,200 |
$793
3,050
kWh
|
- | - | |
| 02 | 2.7234: Use heat pump for space conditioning | $978 | $30,000 | - |
$318
-
MMBtu
|
$660
-
MMBtu
|
|
| 03 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $70 | $6,000 |
$13
50
kWh
|
$57
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $1,841 | $41,200 |
$806
3,100
kWh
|
$375
-
MMBtu
|
$660
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,771 | $35,200 |
$793
3,050
kWh
|
$318
-
MMBtu
|
$660
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs