| Assessment Year | 2021 |
|---|---|
| Principal Product | Laundry Equipment |
| NAICS | 335224: Household Laundry Equipment Manufacturing |
| SIC | 3633: Household Laundry Equipment |
| Sales Range | greater than $500 M |
| # of Employees | 3,200 |
| Plant Area |
1,643,900
ft2
|
| Annual Production | 4,603,897
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $2,666,045 | 79,445,882 |
kWh
|
$0.034 | |
| Electricity Demand | $3,572,264 | 151,111 |
kW-mo/yr
|
$23.64 | |
| Natural Gas | $1,046,091 | 391,253 |
MMBtu
|
$2.67 | |
| Waste Disposal Costs | |||||
| Water Usage | $528,636 | 82,204 |
Tgal
|
$6.43 | |
| Water Disposal | $148,271 | 16,857 |
Tgal
|
$8.80 | |
| TOTAL YEARLY COSTS | $7,961,307 | ||||
| RECOMMENDED SAVINGS* | $722,857 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $221,246 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,601 | - |
$1,910
56,913
kWh
|
$2,691
-
kW-mo/yr
|
- | |
| 02 | 2.7241: Install outside air damper / economizer on hvac unit | $174,302 | $45,000 |
$39,727
1,182,777
kWh
|
$29,735
-
kW-mo/yr
|
$104,840
-
MMBtu
|
|
| 03 | 2.7224: Reduce space conditioning during non-working hours | $58,812 | $45,000 |
$24,430
727,344
kWh
|
$34,382
-
kW-mo/yr
|
- | |
| 04 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $441,982 | $200,000 |
$182,372
5,434,523
kWh
|
$259,610
-
kW-mo/yr
|
- | |
| 05 | 2.2628: Utilize a less expensive cooling method | $42,343 | $88,894 |
$17,578
523,800
kWh
|
$24,765
-
kW-mo/yr
|
- | |
| 06 | 2.2625: Chill water to the highest temperature possible | $817 | - |
$817
24,349
kWh
|
- | - | |
| TOTAL RECOMMENDED | $722,857 | $378,894 |
$266,834
7,949,706
kWh
|
$351,183
-
kW-mo/yr
|
$104,840
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $221,246 | $133,894 |
$59,215
1,763,490
kWh
|
$57,191
-
kW-mo/yr
|
$104,840
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs