Assessment Year | 2017 |
---|---|
Principal Product | Printing Ink |
NAICS | 325910: Printing Ink Manufacturing |
SIC | 2893: Printing Ink |
Sales Range | $50 M to 100M |
# of Employees | 75 |
Plant Area |
80,000
ft2
|
Annual Production | 30,800,000
units
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $150,764 | 3,516,000 |
kWh
|
$0.043 | |
Electricity Demand | $117,822 | 7,632 |
kW-mo/yr
|
$15.44 | |
Electricity Fees | $1,236 | - |
|
- | |
Natural Gas | $39,006 | 16,150 |
MMBtu
|
$2.42 | |
Waste Disposal Costs | |||||
Water Usage | $4,201 | 162 |
Tgal
|
$26.00 | |
Water Disposal | $3,911 | 162 |
Tgal
|
$24.20 | |
TOTAL YEARLY COSTS | $316,940 | ||||
RECOMMENDED SAVINGS* | $19,735 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $1,551 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2628: Utilize a less expensive cooling method | $570 | - |
$570
13,338
kWh
|
- | - | - | |
02 | 2.7224: Reduce space conditioning during non-working hours | $142 | - |
$44
1,030
kWh
|
- |
$98
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,577 | $49,400 |
$9,275
217,056
kWh
|
$4,791
-
kW-mo/yr
|
- | $511 | |
04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,698 | $2,000 |
$1,698
39,732
kWh
|
- | - | - | |
05 | 2.7131: Add area lighting switches | $541 | $250 |
$244
5,715
kWh
|
$177
-
kW-mo/yr
|
- | $120 | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,745 | $1,000 |
$1,149
26,990
kWh
|
$596
-
kW-mo/yr
|
- | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $298 | $1,000 |
$298
6,975
kWh
|
- | - | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $164 | $50 |
$108
2,520
kWh
|
$56
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $19,735 | $53,700 |
$13,386
313,356
kWh
|
$5,620
-
kW-mo/yr
|
$98
-
MMBtu
|
$631 | ||
TOTAL IMPLEMENTED | $1,551 | $1,250 |
$1,156
27,058
kWh
|
$177
-
kW-mo/yr
|
$98
-
MMBtu
|
$120 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs