Assessment Year | 2014 |
---|---|
Principal Product | Recycled Plastics |
NAICS | 325211: Plastics Material and Resin Manufacturing |
SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
Sales Range | $10 M to 50M |
# of Employees | 28 |
Plant Area |
60,000
ft2
|
Annual Production | 14,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $224,731 | 3,155,250 |
kWh
|
$0.071 |
Electricity Demand | $51,012 | 5,880 |
kW-mo/yr
|
$8.68 |
Natural Gas | $4,138 | 349 |
MMBtu
|
$11.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $73,664 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $49,340 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Administrative Changes Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $10,376 | - |
$9,368
133,786
kWh
|
$1,008
-
kW-mo/yr
|
- | - | - | |
02 | 2.5123: Reduce fluid flow rates | $3,671 | - | - | - |
$1,736
-
Tgal
|
- |
$1,935
-
Tgal
|
|
03 | 3.4115: Recover and reuse cooling water | $3,388 | - |
$(-3,203.0)
(-45,744)
kWh
|
$(-345.0)
-
kW-mo/yr
|
$3,280
-
Tgal
|
- |
$3,656
-
Tgal
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $35,576 | $13,517 |
$30,339
433,290
kWh
|
$3,265
-
kW-mo/yr
|
- | $1,972 | - | |
05 | 2.2223: Enhance sensitivity of temperature control and cutoff | $14,607 | $30,000 |
$13,188
188,340
kWh
|
$1,419
-
kW-mo/yr
|
- | - | - | |
06 | 2.2511: Insulate bare equipment | $6,046 | $6,000 |
$5,459
77,964
kWh
|
$587
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $73,664 | $49,517 |
$55,151
787,636
kWh
|
$5,934
-
kW-mo/yr
|
$5,016
-
Tgal
|
$1,972 |
$5,591
-
Tgal
|
||
TOTAL IMPLEMENTED | $49,340 | $13,517 |
$36,504
521,332
kWh
|
$3,928
-
kW-mo/yr
|
$3,280
-
Tgal
|
$1,972 |
$3,656
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Administrative Changes Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs