Assessment Year | 2014 |
---|---|
Principal Product | Quartz Tubing and Shapes |
NAICS | 325199: All Other Basic Organic Chemical Manufacturing |
SIC | 3297: Nonclay Refractories |
Sales Range | $50 M to 100M |
# of Employees | 200 |
Plant Area |
175,300
ft2
|
Annual Production | 25,700,000
units
|
Production Hrs. Annual | 4,080
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,086,155 | 43,946,826 |
kWh
|
$0.047 |
Electricity Demand | $30,685 | 8,161 |
kW-mo/yr
|
$3.76 |
Natural Gas | $1,449,071 | 334,048 |
MMBtu
|
$4.34 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $472,758 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $404,309 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $15,645 | $1,000 |
$15,645
329,583
kWh
|
- | - | - | - | |
02 | 2.7124: Make a practice of turning off lights when not needed | $4,289 | $800 |
$4,289
90,333
kWh
|
- | - | - | - | |
03 | 2.7135: Install occupancy sensors | $1,149 | $190 |
$1,064
22,431
kWh
|
- | - | $85 | - | |
04 | 3.4115: Recover and reuse cooling water | $221,902 | $100,000 | - | - |
$131,962
-
Tgal
|
- |
$89,940
-
Tgal
|
|
05 | 2.5123: Reduce fluid flow rates | $151,019 | $100,000 | - |
$126,019
-
MMBtu
|
- | $25,000 | - | |
06 | 2.4113: Install motor voltage controller on lightly loaded motors | $25,546 | $28,000 |
$25,546
538,150
kWh
|
- | - | - | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,426 | - |
$4,426
93,243
kWh
|
- | - | - | - | |
08 | 2.6242: Minimize operation of equipment maintained in standby condition | $3,748 | $1,000 |
$3,748
78,946
kWh
|
- | - | - | - | |
09 | 2.4113: Install motor voltage controller on lightly loaded motors | $2,267 | $8,850 |
$2,267
47,762
kWh
|
- | - | - | - | |
10 | 2.7314: Reduce ventilation air | $31,388 | $33,025 |
$9,913
208,828
kWh
|
$21,475
-
MMBtu
|
- | - | - | |
11 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,379 | $16,055 |
$7,269
153,135
kWh
|
$4,110
-
MMBtu
|
- | - | - | |
TOTAL RECOMMENDED | $472,758 | $288,920 |
$74,167
1,562,411
kWh
|
$151,604
-
MMBtu
|
$131,962
-
Tgal
|
$25,085 |
$89,940
-
Tgal
|
||
TOTAL IMPLEMENTED | $404,309 | $233,025 |
$9,913
208,828
kWh
|
$147,494
-
MMBtu
|
$131,962
-
Tgal
|
$25,000 |
$89,940
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs