Assessment Year | 2013 |
---|---|
Principal Product | Plastic Mirrors, Skylights |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 22 |
Plant Area |
95,000
ft2
|
Annual Production | 405,000
pieces
|
Production Hrs. Annual | 1,872
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $107,373 | 1,438,800 |
kWh
|
$0.075 |
Electricity Demand | $28,542 | 5,454 |
kW-mo/yr
|
$5.23 |
Natural Gas | $3,606 | 481 |
MMBtu
|
$7.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,836 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,781 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $162 | $200 |
$162
2,080
kWh
|
- | - | - | |
02 | 2.4322: Use or replace with energy efficient substitutes | $1,065 | $1,600 |
$796
10,234
kWh
|
$269
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $638 | $500 |
$701
9,016
kWh
|
$237
-
kW-mo/yr
|
- | $(-300.0) | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $417 | - |
$312
4,013
kWh
|
$105
-
kW-mo/yr
|
- | - | |
05 | 2.2522: Isolate hot or cold equipment | $16,990 | $7,200 |
$12,700
163,320
kWh
|
$4,290
-
kW-mo/yr
|
- | - | |
06 | 2.7224: Reduce space conditioning during non-working hours | $1,564 | $976 | - | - |
$1,564
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $20,836 | $10,476 |
$14,671
188,663
kWh
|
$4,901
-
kW-mo/yr
|
$1,564
-
MMBtu
|
$(-300.0) | ||
TOTAL IMPLEMENTED | $2,781 | $1,676 |
$1,175
15,109
kWh
|
$342
-
kW-mo/yr
|
$1,564
-
MMBtu
|
$(-300.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs