ITAC Assessment: UD0854
ITAC logo
ITAC Assessment: UD0854
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2012
Principal Product microchannel technology
NAICS 333249: Other Industrial Machinery Manufacturing
SIC 3559: Special Industry Machinery, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 60
Plant Area 22,000
ft2
Annual Production 4
units
Production Hrs. Annual 2,000
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $118,279 1,612,200
kWh
Electricity Demand $32,114 3,756
kW-mo/yr
Natural Gas $24,193 3,448
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $103,568 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.9114: Use solar heat to make electricty $77,312 $545,213 $77,312
217,518
kWh
- -
02 2.6224: Schedule baking times of small and large components $5,889 - - $5,889
-
kW-mo/yr
-
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $291 - $225
3,841
kWh
$66
-
kW-mo/yr
-
04 2.2437: Recover waste heat from equipment $1,511 $1,500 $243
4,149
kWh
$49
-
kW-mo/yr
$1,219
-
MMBtu
05 2.4239: Eliminate or reduce compressed air usage $1,351 - $1,126
19,192
kWh
$225
-
kW-mo/yr
-
06 2.7314: Reduce ventilation air $8,795 - $3,239
55,200
kWh
- $5,556
-
MMBtu
07 2.7224: Reduce space conditioning during non-working hours $7,906 - $3,586
61,110
kWh
- $4,320
-
MMBtu
08 2.7491: Insulate glazing, walls, ceilings, and roofs $513 $857 $199
3,400
kWh
$314
-
kW-mo/yr
-
TOTAL RECOMMENDED $103,568 $547,570 $85,930
364,410
kWh
$6,543
-
kW-mo/yr
$11,095
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs