Assessment Year | 2012 |
---|---|
Principal Product | microchannel technology |
NAICS | 333249: Other Industrial Machinery Manufacturing |
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
22,000
ft2
|
Annual Production | 4
units
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $118,279 | 1,612,200 |
kWh
|
$0.073 |
Electricity Demand | $32,114 | 3,756 |
kW-mo/yr
|
$8.55 |
Natural Gas | $24,193 | 3,448 |
MMBtu
|
$7.02 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $103,568 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $77,312 | $545,213 |
$77,312
217,518
kWh
|
- | - | |
02 | 2.6224: Schedule baking times of small and large components | $5,889 | - | - |
$5,889
-
kW-mo/yr
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $291 | - |
$225
3,841
kWh
|
$66
-
kW-mo/yr
|
- | |
04 | 2.2437: Recover waste heat from equipment | $1,511 | $1,500 |
$243
4,149
kWh
|
$49
-
kW-mo/yr
|
$1,219
-
MMBtu
|
|
05 | 2.4239: Eliminate or reduce compressed air usage | $1,351 | - |
$1,126
19,192
kWh
|
$225
-
kW-mo/yr
|
- | |
06 | 2.7314: Reduce ventilation air | $8,795 | - |
$3,239
55,200
kWh
|
- |
$5,556
-
MMBtu
|
|
07 | 2.7224: Reduce space conditioning during non-working hours | $7,906 | - |
$3,586
61,110
kWh
|
- |
$4,320
-
MMBtu
|
|
08 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $513 | $857 |
$199
3,400
kWh
|
$314
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $103,568 | $547,570 |
$85,930
364,410
kWh
|
$6,543
-
kW-mo/yr
|
$11,095
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs