Assessment Year | 2006 |
---|---|
Principal Product | Aluminum and Steel |
NAICS | 339991: Gasket, Packing, and Sealing Device Manufacturing |
SIC | 3053: Gaskets, Packing, and Sealing Devices |
Sales Range | $100 M to 500M |
# of Employees | 130 |
Plant Area |
85,000
ft2
|
Annual Production | 120
ton
|
Production Hrs. Annual | 4,400
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $86,715 | 1,318,120 |
kWh
|
$0.066 |
Natural Gas | $23,093 | 2,053 |
MMBtu
|
$11.25 |
Fuel Oil #1 | $216,900 | 1,172 |
MMBtu
|
$185.07 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $448,037 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,049 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.515: Install shelves / racks to utilize unused space | $432,000 | $143,750 | - | - | - | $432,000 | |
02 | 2.6218: Turn off equipment when not in use | $7,546 | - |
$7,546
125,767
kWh
|
- | - | - | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $6,200 | $840 | - | - |
$6,200
-
MMBtu
|
- | |
04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,988 | $2,960 |
$1,988
18,975
kWh
|
- | - | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $303 | $108 |
$270
4,505
kWh
|
$33
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $448,037 | $147,658 |
$9,804
149,247
kWh
|
$33
-
kW-mo/yr
|
$6,200
-
MMBtu
|
$432,000 | ||
TOTAL IMPLEMENTED | $14,049 | $948 |
$7,816
130,272
kWh
|
$33
-
kW-mo/yr
|
$6,200
-
MMBtu
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs