Assessment Year | 2005 |
---|---|
Principal Product | Freezers & Standard Appliances |
NAICS | 335222: Household Refrigerator and Home Freezer Manufacturing |
SIC | 3632: Household Refrigerators and HOme and Farm Freezers |
Sales Range | $50 M to 100M |
# of Employees | 321 |
Plant Area |
550,000
ft2
|
Annual Production | 416,000
pieces
|
Production Hrs. Annual | 3,840
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $187,456 | 9,170,050 |
kWh
|
$0.020 |
Electricity Demand | $151,263 | 23,016 |
kW-mo/yr
|
$6.57 |
Natural Gas | $268,139 | 32,687 |
MMBtu
|
$8.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,104 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,614 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,715 | $60 |
$5,572
222,912
kWh
|
$3,143
-
kW-mo/yr
|
- | - | - | |
02 | 2.4224: Upgrade controls on compressors | $8,635 | $1,000 |
$5,376
215,040
kWh
|
$3,259
-
kW-mo/yr
|
- | - | - | |
03 | 2.8114: Change rate schedules or other changes in utility service | $8,212 | $22,500 | - | - | $8,712 | - | $(-500.0) | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $6,955 | $20,660 | - | - | - |
$6,955
-
MMBtu
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,839 | $839 |
$1,733
69,312
kWh
|
$1,106
-
kW-mo/yr
|
- | - | - | |
06 | 4.452: Eliminate shift | $2,256 | - |
$2,256
90,240
kWh
|
- | - | - | - | |
07 | 2.4131: Size electric motors for peak operating efficiency | $2,166 | $525 |
$1,351
54,040
kWh
|
$815
-
kW-mo/yr
|
- | - | - | |
08 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,616 | $1,000 |
$1,616
64,653
kWh
|
- | - | - | - | |
09 | 2.4226: Use / purchase optimum sized compressor | $1,498 | - |
$1,498
59,904
kWh
|
- | - | - | - | |
10 | 2.7124: Make a practice of turning off lights when not needed | $953 | - |
$546
21,840
kWh
|
$407
-
kW-mo/yr
|
- | - | - | |
11 | 2.6212: Turn off equipment during breaks, reduce operating time | $259 | $1,000 |
$259
10,368
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $44,104 | $47,584 |
$20,207
808,309
kWh
|
$8,730
-
kW-mo/yr
|
$8,712 |
$6,955
-
MMBtu
|
$(-500.0) | ||
TOTAL IMPLEMENTED | $22,614 | $3,424 |
$14,291
571,672
kWh
|
$8,323
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs