Assessment Year | 2003 |
---|---|
Principal Product | injection molded plastic parts |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 26 |
Plant Area |
35,000
ft2
|
Annual Production | 7,785,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $48,900 | 1,275,680 |
kWh
|
$0.038 |
Electricity Demand | $62,200 | 5,244 |
kW-mo/yr
|
$11.86 |
Natural Gas | $7,641 | 1,083 |
MMBtu
|
$7.06 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $38,005 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,720 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Personnel Changes Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.424: Improve space comfort conditioning | $30,335 | $50,000 | - | - | - | $3,085 | $27,250 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,720 | $11,700 |
$1,400
40,000
kWh
|
$1,320
-
kW-mo/yr
|
- | - | - | |
03 | 2.2511: Insulate bare equipment | $2,600 | $4,625 |
$1,730
52,400
kWh
|
$870
-
kW-mo/yr
|
- | - | - | |
04 | 2.6241: Reduce temperature of process equipment when on standby | $1,225 | - |
$1,225
37,065
kWh
|
- | - | - | - | |
05 | 3.4116: Meter recycled water (to reduce sewer charges) | $925 | - | - | - |
$925
-
Tgal
|
- | - | |
06 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $200 | - |
$200
6,000
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $38,005 | $66,325 |
$4,555
135,465
kWh
|
$2,190
-
kW-mo/yr
|
$925
-
Tgal
|
$3,085 | $27,250 | ||
TOTAL IMPLEMENTED | $2,720 | $11,700 |
$1,400
40,000
kWh
|
$1,320
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Personnel Changes Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs