Assessment Year | 2000 |
---|---|
Principal Product | Recreational vehicles |
NAICS |
n/a
|
SIC | 3792: Travel Trailers and Campers |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
94,000
ft2
|
Annual Production | 3,800
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $31,523 | 1,124,560 |
kWh
|
$0.028 |
Electricity Demand | $43,735 | 4,860 |
kW-mo/yr
|
$9.00 |
Natural Gas | $28,924 | 5,229 |
MMBtu
|
$5.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $88,323 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $163 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 3.2176: Increase use of automation | $80,000 | $287,000 | - | - | - | $80,000 | |
02 | 2.2437: Recover waste heat from equipment | $6,210 | $3,000 | - | - |
$6,210
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,950 | $2,820 |
$750
24,912
kWh
|
$1,200
-
kW-mo/yr
|
- | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $163 | - |
$68
2,345
kWh
|
$95
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $88,323 | $292,820 |
$818
27,257
kWh
|
$1,295
-
kW-mo/yr
|
$6,210
-
MMBtu
|
$80,000 | ||
TOTAL IMPLEMENTED | $163 | - |
$68
2,345
kWh
|
$95
-
kW-mo/yr
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs