Assessment Year | 2000 |
---|---|
Principal Product | Polymer pellets for injection molding |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
250,000
ft2
|
Annual Production | 35,000,000
lb
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $338,898 | 9,685,522 |
kWh
|
$0.035 |
Electricity Demand | $235,984 | 23,040 |
kW-mo/yr
|
$10.24 |
LPG | $57,130 | 11,747 |
MMBtu
|
$4.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $759,606 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $643,500 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.625: Develop standard operating procedures | $643,500 | $150,000 | - | - | - | $643,500 | |
02 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $91,844 | - | - | - |
$91,844
-
lb
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,455 | $31,020 |
$10,306
294,549
kWh
|
$5,149
-
kW-mo/yr
|
- | - | |
04 | 4.111: Add equipment/ operators to reduce production bottleneck | $8,807 | $7,600 | - |
$4,032
-
kW-mo/yr
|
- | $4,775 | |
TOTAL RECOMMENDED | $759,606 | $188,620 |
$10,306
294,549
kWh
|
$9,181
-
kW-mo/yr
|
$91,844
-
lb
|
$648,275 | ||
TOTAL IMPLEMENTED | $643,500 | $150,000 | - | - | - | $643,500 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs