Assessment Year 2000
Principal Product multi-walled bags
NAICS
n/a
SIC 2674: Uncoated Paper and Multiwall Bags
Sales Range $10
M
to 50
M
# of Employees 219
Plant Area 148,000
ft2
Annual Production 126,000,000
pieces
Production Hrs. Annual 6,600
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $69,997 2,788,687
kWh
Electricity Demand $86,953 6,180
kW-mo/yr
Natural Gas $26,363 5,364
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $335,232 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $342

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Administrative Changes Savings Primary Product Savings
01 3.1193: Convert from batch operation to continuous processing $189,338 $180,000 - - - - $189,338
02 4.445: Install equipment to move product $145,552 $100,000 - - $96,000 $49,552 -
03 2.7134: Use photocell controls $342 - $128
11,137
kWh
$214
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $335,232 $280,000 $128
11,137
kWh
$214
-
kW-mo/yr
$96,000 $49,552 $189,338
TOTAL IMPLEMENTED $342 - $128
11,137
kWh
$214
-
kW-mo/yr
- - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs