Assessment Year | 2000 |
---|---|
Principal Product | Ultrasonic machining of silicon |
NAICS |
n/a
|
SIC | 3699: Electrical Machinery, Equipment, and Supplies, Not Elsewhere |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
70,000
ft2
|
Annual Production | 15,000
pieces
|
Production Hrs. Annual | 6,600
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $70,952 | 2,751,172 |
kWh
|
$0.026 |
Electricity Demand | $91,511 | 6,504 |
kW-mo/yr
|
$14.07 |
Natural Gas | $4,952 | 863 |
MMBtu
|
$5.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $74,260 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,705 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Fees Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 4.631: Install an uninteruptable power supply | $52,000 | $172,190 | - | - | - | - | $(-8,000.0) | $60,000 | |
02 | 2.8114: Change rate schedules or other changes in utility service | $8,705 | - | $8,705 | - | - | - | - | - | |
03 | 3.3111: Adjust ph for neutralization | $7,560 | $30,000 | - | - |
$7,560
-
gal
|
- | - | - | |
04 | 2.2437: Recover waste heat from equipment | $4,045 | $3,000 | - |
$4,045
-
MMBtu
|
- | - | - | - | |
05 | 3.5217: Reuse / recycle/ sell paper products | $1,950 | - | - | - | - |
$1,950
-
lb
|
- | - | |
TOTAL RECOMMENDED | $74,260 | $205,190 | $8,705 |
$4,045
-
MMBtu
|
$7,560
-
gal
|
$1,950
-
lb
|
$(-8,000.0) | $60,000 | ||
TOTAL IMPLEMENTED | $8,705 | - | $8,705 | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs