| Assessment Year | 1998 |
|---|---|
| Principal Product | Fans, blowers, humidifiers, air moving equipment & blower wh |
| NAICS |
n/a
|
| SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
186,000
ft2
|
| Annual Production | 260,000
pieces
|
| Production Hrs. Annual | 7,344
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $126,979 | 5,590,563 |
kWh
|
$0.023 |
| Electricity Demand | $150,021 | 10,824 |
kW-mo/yr
|
$13.86 |
| Natural Gas | $145,032 | 36,427 |
MMBtu
|
$3.98 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $59,166 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $21,309 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 4.652: Replace existing equipment with more suitable substitutes | $18,360 | $25,000 | - | - | - | - | $18,360 | |
| 02 | 4.623: Employ modular jigs to reduce process set-up time | $13,770 | $5,000 | - | - | - | - | $13,770 | |
| 03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $12,474 | - | - |
$12,474
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $3,779 | $454 |
$1,660
82,943
kWh
|
$2,067
-
kW-mo/yr
|
- | $52 | - | |
| 05 | 4.431: Train operators for maximum operating efficiency | $3,469 | - | - | - | - | $3,469 | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,782 | $500 |
$1,304
65,358
kWh
|
$1,478
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.2425: Use flue gases to heat process or service water | $1,752 | $2,000 | - | - |
$1,752
-
MMBtu
|
- | - | |
| 08 | 2.2437: Recover waste heat from equipment | $1,492 | $1,060 |
$(-130.0)
(-6,448)
kWh
|
$(-150.0)
-
kW-mo/yr
|
$1,772
-
MMBtu
|
- | - | |
| 09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,288 | - |
$165
8,206
kWh
|
$1,123
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $59,166 | $34,014 |
$2,999
150,059
kWh
|
$16,992
-
kW-mo/yr
|
$3,524
-
MMBtu
|
$3,521 | $32,130 | ||
| TOTAL IMPLEMENTED | $21,309 | $5,500 |
$1,469
73,564
kWh
|
$2,601
-
kW-mo/yr
|
- | $3,469 | $13,770 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs