Assessment Year | 1998 |
---|---|
Principal Product | Gears, Sprockets, Splines, & Racks |
NAICS |
n/a
|
SIC | 3566: Speed Changers, Industrial High-Speed Drives, and Gears |
Sales Range | $1 M to 5M |
# of Employees | 24 |
Plant Area |
16,000
ft2
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 3,300
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $4,810 | 184,936 |
kWh
|
$0.026 |
Electricity Demand | $10,975 | 780 |
kW-mo/yr
|
$14.07 |
Natural Gas | $4,152 | 790 |
MMBtu
|
$5.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,549 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,935 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,935 | $5,622 |
$652
14,947
kWh
|
$1,283
-
kW-mo/yr
|
- | - | |
02 | 2.8112: Combine utility meters | $1,070 | $300 | - |
$(-1,182.0)
-
kW-mo/yr
|
$2,252 | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $624 | - |
$180
7,034
kWh
|
$444
-
kW-mo/yr
|
- | - | |
04 | 4.652: Replace existing equipment with more suitable substitutes | $1,920 | $2,000 | - | - | - | $1,920 | |
TOTAL RECOMMENDED | $5,549 | $7,922 |
$832
21,981
kWh
|
$545
-
kW-mo/yr
|
$2,252 | $1,920 | ||
TOTAL IMPLEMENTED | $1,935 | $5,622 |
$652
14,947
kWh
|
$1,283
-
kW-mo/yr
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs