Assessment Year | 1997 |
---|---|
Principal Product | Plastic Products, toy balls |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
286,000
ft2
|
Annual Production | 30,000,000
pieces
|
Production Hrs. Annual | 6,480
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $133,105 | 5,787,222 |
kWh
|
$0.023 |
Electricity Demand | $260,021 | 11,112 |
kW-mo/yr
|
$23.40 |
Natural Gas | $355,377 | 107,888 |
MMBtu
|
$3.29 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $149,095 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $27,652 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.4116: Meter recycled water (to reduce sewer charges) | $3,055 | $2,200 | - | - |
$3,055
-
MMBtu
|
- | - | |
02 | 2.4235: Remove or close off unneeded compressed air lines | $3,250 | $5,600 |
$116
4,982
kWh
|
$3,134
-
kW-mo/yr
|
- | - | - | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $34,540 | $37,500 |
$8,208
356,975
kWh
|
$23,888
-
kW-mo/yr
|
$(-4,606.0)
-
MMBtu
|
- | $7,050 | |
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $24,402 | - | - |
$24,402
-
kW-mo/yr
|
- | - | - | |
05 | 4.652: Replace existing equipment with more suitable substitutes | $51,015 | $200,000 | - | - |
$20,043
-
MMBtu
|
$3,072
-
Tgal
|
$27,900 | |
06 | 2.2437: Recover waste heat from equipment | $32,833 | $66,000 |
$(-363.0)
(-15,826)
kWh
|
$(-615.0)
-
kW-mo/yr
|
$33,811
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $149,095 | $311,300 |
$7,961
346,131
kWh
|
$50,809
-
kW-mo/yr
|
$52,303
-
MMBtu
|
$3,072
-
Tgal
|
$34,950 | ||
TOTAL IMPLEMENTED | $27,652 | $5,600 |
$116
4,982
kWh
|
$27,536
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs