| Assessment Year | 1996 |
|---|---|
| Principal Product | Fabricated structural steel, industrial welding |
| NAICS |
n/a
|
| SIC | 3441: Fabricated Structural Metal |
| Sales Range | $5 M to 10M |
| # of Employees | 40 |
| Plant Area |
34,000
ft2
|
| Annual Production | 3,800
ton
|
| Production Hrs. Annual | 2,900
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $11,834 | 374,560 |
kWh
|
$0.032 |
| Electricity Demand | $25,576 | 2,112 |
kW-mo/yr
|
$12.11 |
| LPG | $16,352 | 1,980 |
MMBtu
|
$8.26 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,156 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,228 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.1331: Burn a less expensive grade of fuel | $5,738 | $7,500 | - | - | - |
$(-8,702.0)
-
MMBtu
|
$14,440
-
MMBtu
|
|
| 02 | 2.3137: Use power during off-peak periods | $9,357 | - | - |
$10,317
-
kW-mo/yr
|
$(-960.0) | - | - | |
| 03 | 2.2212: Use minimum safe oven ventilation | $1,228 | $5,000 | - | - | - | - |
$1,228
-
MMBtu
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $833 | $3,271 |
$386
12,309
kWh
|
$563
-
kW-mo/yr
|
- |
$(-116.0)
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $17,156 | $15,771 |
$386
12,309
kWh
|
$10,880
-
kW-mo/yr
|
$(-960.0) |
$(-8,818.0)
-
MMBtu
|
$15,668
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,228 | $5,000 | - | - | - | - |
$1,228
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs