| Assessment Year | 1996 |
|---|---|
| Principal Product | automotive struts |
| NAICS |
n/a
|
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $50 M to 100M |
| # of Employees | 276 |
| Plant Area |
162,000
ft2
|
| Annual Production | 3,000,000
pieces
|
| Production Hrs. Annual | 8,000
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $523,533 | 15,342,028 |
kWh
|
$0.034 |
| Electricity Demand | $290,952 | 32,328 |
kW-mo/yr
|
$9.00 |
| Natural Gas | $55,981 | 11,234 |
MMBtu
|
$4.98 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $65,054 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $56,039 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4239: Eliminate or reduce compressed air usage | $16,063 | $6,000 |
$8,024
235,932
kWh
|
$6,372
-
kW-mo/yr
|
- | $1,667 | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $11,867 | - |
$10,200
300,117
kWh
|
- | - | $1,667 | |
| 03 | 2.4239: Eliminate or reduce compressed air usage | $3,571 | - |
$3,071
90,270
kWh
|
- | - | $500 | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,015 | $17,260 |
$5,725
168,523
kWh
|
$3,145
-
kW-mo/yr
|
$145 | - | |
| 05 | 2.3137: Use power during off-peak periods | $24,538 | - | - |
$24,538
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $65,054 | $23,260 |
$27,020
794,842
kWh
|
$34,055
-
kW-mo/yr
|
$145 | $3,834 | ||
| TOTAL IMPLEMENTED | $56,039 | $6,000 |
$21,295
626,319
kWh
|
$30,910
-
kW-mo/yr
|
- | $3,834 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs