Assessment Year | 1995 |
---|---|
Principal Product | tools and dies |
NAICS |
n/a
|
SIC | 3544: Special Dies and Tools, Die Sets, Jigs and Fixtures, and Industrial Molds |
Sales Range | $5 M to 10M |
# of Employees | 30 |
Plant Area |
40,000
ft2
|
Annual Production | 1,000
pieces
|
Production Hrs. Annual | 5,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $42,788 | 574,443 |
kWh
|
$0.074 |
Natural Gas | $11,932 | 2,498 |
MMBtu
|
$4.78 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,589 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,036 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4237: Substitute compressed air cooling with water or air cooling | $12,036 | $15,000 |
$12,036
158,558
kWh
|
- | - | |
02 | 2.2437: Recover waste heat from equipment | $619 | $2,500 | - |
$619
-
MMBtu
|
- | |
03 | 2.7122: Disconnect ballasts | $934 | $100 |
$1,029
15,240
kWh
|
$(-157.0)
-
MMBtu
|
$62 | |
TOTAL RECOMMENDED | $13,589 | $17,600 |
$13,065
173,798
kWh
|
$462
-
MMBtu
|
$62 | ||
TOTAL IMPLEMENTED | $12,036 | $15,000 |
$12,036
158,558
kWh
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs