Assessment Year | 1995 |
---|---|
Principal Product | clutch assemblies, power steering pumps, rear differentials |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 400 |
Plant Area |
439,000
ft2
|
Annual Production | 110,000
pieces
|
Production Hrs. Annual | 8,200
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $383,319 | 7,214,830 |
kWh
|
$0.053 |
Natural Gas | $45,650 | 8,372 |
MMBtu
|
$5.45 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,948 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,512 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $5,436 | $10,000 |
$5,436
-
kWh
|
- | - | |
02 | 2.8113: Purchase gas directly from a contract gas supplier | $10,000 | $25,000 | - | - | $10,000 | |
03 | 2.7124: Make a practice of turning off lights when not needed | $2,738 | $1,000 |
$2,709
53,341
kWh
|
$(-355.0)
-
MMBtu
|
$384 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,406 | $30,850 |
$11,406
197,538
kWh
|
- | - | |
05 | 2.7122: Disconnect ballasts | $3,368 | $3,000 |
$3,572
70,926
kWh
|
$(-470.0)
-
MMBtu
|
$266 | |
TOTAL RECOMMENDED | $32,948 | $69,850 |
$23,123
321,805
kWh
|
$(-825.0)
-
MMBtu
|
$10,650 | ||
TOTAL IMPLEMENTED | $17,512 | $34,850 |
$17,687
321,805
kWh
|
$(-825.0)
-
MMBtu
|
$650 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs