Assessment Year | 1995 |
---|---|
Principal Product | plastic injection molding |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
40,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $284,285 | 4,674,971 |
kWh
|
$0.061 |
Natural Gas | $9,570 | 1,903 |
MMBtu
|
$5.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $58,311 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $45,870 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $41,888 | $30,000 |
$41,888
-
kWh
|
- | - | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $11,025 | - |
$11,025
321,512
kWh
|
- | - | |
03 | 2.2437: Recover waste heat from equipment | $1,416 | $3,000 | - |
$1,416
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,670 | $5,216 |
$1,458
26,377
kWh
|
- | $212 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,312 | $4,077 |
$2,312
37,808
kWh
|
- | - | |
TOTAL RECOMMENDED | $58,311 | $42,293 |
$56,683
385,697
kWh
|
$1,416
-
MMBtu
|
$212 | ||
TOTAL IMPLEMENTED | $45,870 | $39,293 |
$45,658
64,185
kWh
|
- | $212 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs