| Assessment Year | 1995 |
|---|---|
| Principal Product | auto brake calipers |
| NAICS |
n/a
|
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $50 M to 100M |
| # of Employees | 260 |
| Plant Area |
114,000
ft2
|
| Annual Production | 2,900,000
pieces
|
| Production Hrs. Annual | 7,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $509,034 | 9,926,143 |
kWh
|
$0.051 |
| Natural Gas | $85,525 | 16,134 |
MMBtu
|
$5.30 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $90,437 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $65,988 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $11,292 | $25,000 |
$11,292
-
kWh
|
- | - | - | |
| 02 | 2.8113: Purchase gas directly from a contract gas supplier | $22,105 | $70,000 | - | - | - | $22,105 | |
| 03 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $23,747 | $5,000 |
$23,747
593,200
kWh
|
- | - | - | |
| 04 | 2.2437: Recover waste heat from equipment | $12,040 | $30,000 | - |
$12,040
-
MMBtu
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,553 | $23,127 |
$11,553
242,966
kWh
|
- | - | - | |
| 06 | 2.7123: Keep lamps and reflectors clean | $2,914 | $1,680 |
$2,914
67,702
kWh
|
- | - | - | |
| 07 | 2.7111: Reduce illumination to minimum necessary levels | $2,344 | - |
$2,344
111,665
kWh
|
- | - | - | |
| 08 | 3.4116: Meter recycled water (to reduce sewer charges) | $4,442 | $600 | - | - |
$4,442
-
Tgal
|
- | |
| TOTAL RECOMMENDED | $90,437 | $155,407 |
$51,850
1,015,533
kWh
|
$12,040
-
MMBtu
|
$4,442
-
Tgal
|
$22,105 | ||
| TOTAL IMPLEMENTED | $65,988 | $85,407 |
$49,506
903,868
kWh
|
$12,040
-
MMBtu
|
$4,442
-
Tgal
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs