| Assessment Year | 1995 |
|---|---|
| Principal Product | automotive lighting |
| NAICS |
n/a
|
| SIC | 3647: Vehicular Lighting Equipment |
| Sales Range | $100 M to 500M |
| # of Employees | 412 |
| Plant Area |
288,000
ft2
|
| Annual Production | 650,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,052,688 | 14,656,214 |
kWh
|
$0.072 |
| Natural Gas | $82,251 | 15,794 |
MMBtu
|
$5.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $48,918 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $28,937 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $11,837 | $2,000 |
$11,837
172,919
kWh
|
- | - | |
| 02 | 2.8113: Purchase gas directly from a contract gas supplier | $17,100 | - | - | - | $17,100 | |
| 03 | 2.7124: Make a practice of turning off lights when not needed | $6,981 | $4,440 |
$6,035
87,046
kWh
|
- | $946 | |
| 04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $13,000 | $26,000 |
$20,526
240,035
kWh
|
$(-6,826.0)
-
MMBtu
|
$(-700.0) | |
| TOTAL RECOMMENDED | $48,918 | $32,440 |
$38,398
500,000
kWh
|
$(-6,826.0)
-
MMBtu
|
$17,346 | ||
| TOTAL IMPLEMENTED | $28,937 | $2,000 |
$11,837
172,919
kWh
|
- | $17,100 | ||