Assessment Year | 1994 |
---|---|
Principal Product | windows for mobile homes |
NAICS |
n/a
|
SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
78,000
ft2
|
Annual Production | 48,000
pieces
|
Production Hrs. Annual | 3,250
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $50,696 | 608,148 |
kWh
|
$0.083 |
Natural Gas | $5,727 | 1,099 |
MMBtu
|
$5.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,810 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $27,810 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $22,736 | $16,000 |
$19,429
243,552
kWh
|
$(-1,221.0)
-
MMBtu
|
$4,528 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $595 | $1,280 |
$595
6,155
kWh
|
- | - | |
03 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $4,063 | $10,000 |
$4,063
48,945
kWh
|
- | - | |
04 | 2.2437: Recover waste heat from equipment | $416 | $2,000 |
$107
3,810
kWh
|
$309
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $27,810 | $29,280 |
$24,194
302,462
kWh
|
$(-912.0)
-
MMBtu
|
$4,528 | ||
TOTAL IMPLEMENTED | $27,810 | $29,280 |
$24,194
302,462
kWh
|
$(-912.0)
-
MMBtu
|
$4,528 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs