| Assessment Year | 1994 |
|---|---|
| Principal Product | innerspring units |
| NAICS |
n/a
|
| SIC | 2515: Mattresses, Foundations, and Convertible Beds |
| Sales Range | $10 M to 50M |
| # of Employees | 331 |
| Plant Area |
219,000
ft2
|
| Annual Production | 1,500,000
pieces
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $347,485 | 7,443,435 |
kWh
|
$0.047 |
| Natural Gas | $91,645 | 16,673 |
MMBtu
|
$5.50 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $32,047 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $28,712 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 3.7212: Improved material handling (mixing and transfer) | $3,914 | - | - | - | - | $3,914 | |
| 02 | 2.8113: Purchase gas directly from a contract gas supplier | $3,335 | - | - | - | $3,335 | - | |
| 03 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $12,118 | $1,000 |
$11,740
541,032
kWh
|
$(-2,822.0)
-
MMBtu
|
$3,200 | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,818 | $3,360 |
$1,818
32,825
kWh
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,952 | $6,200 |
$1,952
89,977
kWh
|
- | - | - | |
| 06 | 2.2437: Recover waste heat from equipment | $8,910 | $10,000 | - |
$8,910
-
MMBtu
|
- | - | |
| TOTAL RECOMMENDED | $32,047 | $20,560 |
$15,510
663,834
kWh
|
$6,088
-
MMBtu
|
$6,535 | $3,914 | ||
| TOTAL IMPLEMENTED | $28,712 | $20,560 |
$15,510
663,834
kWh
|
$6,088
-
MMBtu
|
$3,200 | $3,914 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs