Assessment Year | 1994 |
---|---|
Principal Product | machined components and fabrications |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
99,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 8,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $107,745 | 1,941,383 |
kWh
|
$0.055 |
Natural Gas | $25,962 | 5,142 |
MMBtu
|
$5.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,333 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $359 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,799 | - |
$4,799
-
kWh
|
- | |
02 | 2.2437: Recover waste heat from equipment | $1,097 | $1,500 | - |
$1,097
-
MMBtu
|
|
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,349 | $500 |
$2,349
84,408
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,742 | $7,965 |
$3,742
51,583
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $359 | $375 |
$359
4,396
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,987 | $2,500 |
$1,987
20,809
kWh
|
- | |
TOTAL RECOMMENDED | $14,333 | $12,840 |
$13,236
161,196
kWh
|
$1,097
-
MMBtu
|
||
TOTAL IMPLEMENTED | $359 | $375 |
$359
4,396
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs