Assessment Year | 1994 |
---|---|
Principal Product | aluminum beverage can |
NAICS |
n/a
|
SIC | 3411: Metal Cans |
Sales Range | $50 M to 100M |
# of Employees | 86 |
Plant Area |
90,000
ft2
|
Annual Production | 950,000,000
pieces
|
Production Hrs. Annual | 8,300
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $634,534 | 15,092,321 |
kWh
|
$0.042 |
Natural Gas | $251,437 | 73,952 |
MMBtu
|
$3.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $45,764 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,558 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $7,057 | $10,000 |
$7,057
-
kWh
|
- | - | |
02 | 3.4116: Meter recycled water (to reduce sewer charges) | $2,501 | - | - | - |
$2,501
-
MMBtu
|
|
03 | 2.2437: Recover waste heat from equipment | $3,090 | $5,000 | - |
$3,090
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,265 | $6,838 |
$4,265
83,822
kWh
|
- | - | |
05 | 2.7313: Recycle air for heating, ventilation and air conditioning | $28,851 | $50,000 | - |
$28,851
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $45,764 | $71,838 |
$11,322
83,822
kWh
|
$31,941
-
MMBtu
|
$2,501
-
MMBtu
|
||
TOTAL IMPLEMENTED | $9,558 | $10,000 |
$7,057
-
kWh
|
- |
$2,501
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs