| Assessment Year | 1994 |
|---|---|
| Principal Product | blowers, fans |
| NAICS |
n/a
|
| SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 107 |
| Plant Area |
75,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 5,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $53,194 | 711,606 |
kWh
|
$0.075 |
| Natural Gas | $53,194 | 2,428 |
MMBtu
|
$21.91 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $2,310 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,156 | $75,000 |
$1,156
-
kWh
|
|
| 02 | 2.7122: Disconnect ballasts | $382 | $2,400 |
$382
11,430
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $772 | $46,256 |
$772
23,154
kWh
|
|
| TOTAL RECOMMENDED | $2,310 | $123,656 |
$2,310
34,584
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs