Assessment Year | 1993 |
---|---|
Principal Product | polymers and water-based adhesives |
NAICS |
n/a
|
SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
Sales Range | $100 M to 500M |
# of Employees | 80 |
Plant Area |
80,000
ft2
|
Annual Production | 70,000,000
lb
|
Production Hrs. Annual | 8,500
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $182,567 | 4,082,356 |
kWh
|
$0.045 |
Natural Gas | $115,182 | 38,397 |
MMBtu
|
$3.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,839 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,652 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $5,367 | - |
$5,367
-
kWh
|
- | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,994 | $300 | - |
$1,994
-
MMBtu
|
|
03 | 2.2136: Install / repair insulation on steam lines | $3,714 | $10,139 | - |
$3,714
-
MMBtu
|
|
04 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $6,173 | $18,000 | - |
$6,173
-
MMBtu
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $647 | - |
$647
13,775
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,944 | $10,376 |
$4,360
88,218
kWh
|
$(-416.0)
-
MMBtu
|
|
TOTAL RECOMMENDED | $21,839 | $38,815 |
$10,374
101,993
kWh
|
$11,465
-
MMBtu
|
||
TOTAL IMPLEMENTED | $9,652 | $20,815 |
$4,360
88,218
kWh
|
$5,292
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs