Assessment Year 1993
Principal Product sports jackets, shirts, caps
NAICS
n/a
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 125
Plant Area 100,000
ft2
Annual Production 0
units
Production Hrs. Annual 3,000
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $72,756 1,110,199
kWh
Natural Gas $26,826 6,198
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $8,508 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1224: Replace boiler $1,962 - - $1,962
-
MMBtu
02 2.7111: Reduce illumination to minimum necessary levels $334 $300 $334
4,689
kWh
-
03 2.7111: Reduce illumination to minimum necessary levels $1,968 - $1,968
27,843
kWh
-
04 2.7131: Add area lighting switches $4,244 $2,000 $4,244
90,856
kWh
-
TOTAL RECOMMENDED $8,508 $2,300 $6,546
123,388
kWh
$1,962
-
MMBtu
TOTAL IMPLEMENTED - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs