Assessment Year | 1993 |
---|---|
Principal Product | plastic containers |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 101 |
Plant Area |
40,000
ft2
|
Annual Production | 190,000,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $490,555 | 9,781,653 |
kWh
|
$0.050 |
Natural Gas | $8,185 | 1,839 |
MMBtu
|
$4.45 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $79,129 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $52,217 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $26,912 | $34,000 |
$26,912
599,941
kWh
|
- | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $12,218 | - |
$12,218
262,603
kWh
|
- | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $24,501 | $54,400 |
$30,546
656,213
kWh
|
$(-6,045.0)
-
MMBtu
|
|
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,274 | - |
$2,274
-
kWh
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $3,755 | $1,000 |
$4,335
96,717
kWh
|
$(-580.0)
-
MMBtu
|
|
06 | 2.7111: Reduce illumination to minimum necessary levels | $9,469 | $630 |
$10,931
243,552
kWh
|
$(-1,462.0)
-
MMBtu
|
|
TOTAL RECOMMENDED | $79,129 | $90,030 |
$87,216
1,859,026
kWh
|
$(-8,087.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $52,217 | $56,030 |
$60,304
1,259,085
kWh
|
$(-8,087.0)
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs