Assessment Year | 1991 |
---|---|
Principal Product | CONTAINERS |
NAICS |
n/a
|
SIC | 3411: Metal Cans |
Sales Range | $10 M to 50M |
# of Employees | 96 |
Plant Area |
n/a
|
Annual Production | 125,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $197,572 | 4,279,601 |
kWh
|
$0.046 |
Natural Gas | $74,716 | 17,850 |
MMBtu
|
$4.19 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,493 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,554 | - |
$2,800
65,064
kWh
|
$(-464.0)
-
MMBtu
|
$218 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,853 | - |
$3,168
73,564
kWh
|
$(-525.0)
-
MMBtu
|
$210 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,774 | - |
$11,979
278,722
kWh
|
$(-1,987.0)
-
MMBtu
|
$782 | |
04 | 2.4239: Eliminate or reduce compressed air usage | $14,828 | $500 |
$9,030
209,848
kWh
|
$1,498
-
MMBtu
|
$4,300 | |
05 | 3.4115: Recover and reuse cooling water | $1,484 | - | - | - | $1,484 | |
TOTAL RECOMMENDED | $32,493 | $500 |
$26,977
627,198
kWh
|
$(-1,478.0)
-
MMBtu
|
$6,994 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs